Ozone oxidation
New equipment was installed in which kg scale ozone oxidation, organometallic
reactions, and so on are conducted. The equipment is a 150L teflon lined
vessel in which the reactions can be conducted at temperatures between
-100 to +120 and the equipment accommodates a monitor for thermal activity,
a monitor for dropping amount, a monitor for gas current and also accommodates
a auto controller of dropping amount. The equipment also accommodates ozone
generator.
|
Extraction, separation and purification
Extraction, separation and purification are conducted by the combination
of various techniques and apparatus (large scale medium pressure chromatography,
preparative HPLC, countercurrent chromatography, distillation, centrifugal
molecular distillation, membrane separation, re-crystallization, sublimation
and so on). Extraction, separation and purification are conducted on contract
agreement basis covering large areas. The areas are as follows; removal
of a trace amount of impurities from chemically synthesized materials,
extraction of active ingredients from pharmaceutical or agrochemical materials,
or natural products, or natural medicines, and extraction, separation and
purification of secondary metabolites from blood or urine. Scale range
is from mgs to kgs.
|